<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>15355</ErrorNumber>
<ErrorFamily>Autoloader</ErrorFamily>
<ErrorMessage>
ALE: STEP : axis 1 aborted while moving
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Trendsetter_400/800_Proofing</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<OperatorAction>
<DescriptionText><text>
Make sure that the red ABORT button is not pushed in.  Then select the
RESUME button from the workstation dialog box. If
the problem persists, call Creo Service.
</text></DescriptionText>
</OperatorAction>
<ServiceInformation>
<DescriptionText><text>
Make sure that the red ABORT button is not pushed in. Type "mask" to see the
status of the hardware abort line. If there is an exclamation mark (!) preceding
"ABORT switch on" , then the hardware abort line is active. If the ABORT button
is not pressed in, then there is a problem with the abort switch wiring. Check
the door sensor connector (J19) on the card-cage backplane.
</text></DescriptionText>
</ServiceInformation>
<Cause>
An ABORT command was issued from the diagnostic monitor, or the red ABORT button
was pressed while the stepper motor was moving.
</Cause>
<SeeAlso>
<UnnumberedList>
<Link><LinkAddress>../commands/mask.xml</LinkAddress><LinkTitle>Command: mask</LinkTitle></Link>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:33:04 2008 PST
</Updated>
<Links>
</Links>
</Error>